XPR® Rev. N firmware upgrade

On April 13, we released new XPRTM firmware for the Control board (WiFi, Torch connect, Gas connect, and Chopper) firmware remains the same. After the XPRTM is updated, the new firmware will transition revision levels as shown below:

There are numerous improvements enabled in these releases:

1. Changed mixer I2C fault behavior. I2C warnings do not end cut, I2C errors end cut only if using mix process.
2. Resolved false node reset 691 errors.
3. Resolved motion signal issue. Changed all lost current errors to now end the cut.
4. Added main control 24vdc high voltage 784 error.
5. Added stop cut and prevent start if low speed MagFan 2, 745 error – limit for XPR170TM only.
6. Resolved inductor 4 temperature scaling error reporting.

The new firmware is available for upload on Xnet. Up-revved versions of the XPR300TM Instruction Manual (809480 ), XPR170TM Instruction Manual (810060) and XPR CNC Communication Protocol (809810) can be downloaded.

At the same time, Up-revved Phoenix® software (version 10.15.0) is released to the field.